Alternate Breakdown Voltages |
|
|
SP-LP-RPTNC Information The SP-LP-RPTNC Lightning Protector is a
gas discharge tube suppressor featuring wide-band operation up to 3
GHz. This unit features a Reverse-Polarity TNC-Plug to
Reverse-Polarity TNC-Jack Bulkhead connector with a rubber O-ring seal
for mounting through an enclosure wall or with the included aluminum
mounting bracket. Due to its low cost and superior RF performance,
this unit is ideal for IEEE 802.11b/g Wireless LAN applications, as
well as ISM, MMDS, Cellular, and PCS applications. Since this
protector will pass DC, it is suitable for applications where DC is
carried through the coax cable, such as remote amplifiers and LNAs.
Both connector ports of this unit are equally protected. This provides
protection no matter which way it is installed. Either port can face
the antenna and either port can face the equipment. The unit's
replaceable gas tube element, multi-strike capability, and fast
response time make it suitable for a wide range of applications. A
ground lug and terminal are supplied directly on the lightning
protector housing, which provides superior grounding. Features
- Reliable Performance from DC ~ 3 GHz
- Competitively Priced
- High Quality Construction
- Easily Replaced Gas Tube Element
- Multi-Strike Capability
- Bi-Directional Protection
- Protector will pass DC
- Mounting Bracket and Hardware Included
|
Electrical Specifications |
| Frequency Range |
0 - 3 GHz |
| Protector Complies With |
IEC / IEEE Standard |
| VSWR |
1:1.3 Max (0 - 3 GHz) |
| Insertion Loss |
0.4 dB Max (0 - 3GHz) |
| Impedance |
50 Ohm |
Standard Gas Tube Element:
DC Breakdown Voltage Indicated |
90 V ± 20% |
Available Gas Tube Elements:
DC Breakdown Voltages Indicated |
230 V ± 20%
350 V ± 20%
600 V ± 20% |
| Gas Tube Impulse Breakdown
Voltage |
1000 V ± 20% |
| Gas Tube Insulation Resistance |
10,000 MΩ |
| Maximum Withstand Current |
5 KA |
|
RF Power Rating |
Model
Suffix |
Voltage
Rating |
DC ~ 30MHz |
30–500MHz |
500MHz–3GHz |
| PEP1 |
CW2 |
PEP1 |
CW2 |
PEP1 |
CW2 |
| -9 |
90 Volt |
110W |
55W |
65W |
32W |
20W |
10W |
| -2 |
230 Volt |
280W |
140W |
110W |
55W |
40W |
20W |
| -3 |
350 Volt |
650W |
325W |
260W |
130W |
100W |
50W |
| -6 |
600 Volt |
2KW |
1KW |
800W |
400W |
320W |
160W |
|
|
Mechanical Specifications |
| Connectors Comply With |
MIL-C-71A, 39012 Standard |
| Connectors Types |
Reverse-Polarity TNC-Plug to Reverse-Polarity
TNC-Jack Bulkhead |
| Connector Body Material |
Nickel Plated Brass |
| Body Material |
Aluminum |
| Pin Material |
Gold Plated Brass |
| O-Ring Material |
Rubber |
| Bracket Material |
Aluminum |
| Dimensions (L x H x W) |
3.2 in x 1.6 in x 0.8 in
(82 mm x 40 mm x 20 mm) |
| Weight |
3.17oz
(89.8g) |
|
Environmental Specifications |
| Temperature
Range |
-67°F to 185°F
(-55°C to +85°C) |
| Dust and
Waterproof Rating |
IEC 529 / IP65 |
| Moisture
Resistance |
MIL-STD-202 Method 106D |
| Salt Fog |
MIL-STD-202 101D/B |
| Temperature
Shock |
MIL-STD-202 107D/A-1 |
| Vibration |
MIL-STD-202 Method 204D/B |
| Shock |
MIL-STD-202 Method 213B/A |
|